| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Attackers can then execute malicious files by enabling certain services of the printer via the web configuration page and elevate its privileges to root. As for the affected products/models/versions, see the reference URL. |
| The authenticated SCU firmware command of the firmware for Mennekes Smart / Premium Chargingpoints can be abused for command execution because OS commands are improperly neutralized when certain fields are passed to the underlying OS. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authorization logic of the affected device allows an authenticated, low-privileged user to execute the administrative `ping` function, which is restricted to higher-privileged roles. This vulnerability enables the user to perform internal network reconnaissance, potentially discovering internal hosts or services that would otherwise be inaccessible. Repeated exploitation could lead to minor resource consumption. While the overall impact is limited, it may result in some loss of confidentiality and availability on the affected device. There is no impact on the integrity of the device, and the vulnerability does not affect any subsequent systems. |
| An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in broken access control has been identified in the /api/v1/setting/data endpoint of the affected device. This flaw allows a low-privileged authenticated user to call the API without the required permissions, thereby gaining the ability to access or modify system configuration data. Successful exploitation may lead to privilege escalation, allowing the attacker to access or modify sensitive system settings. While the overall impact is high, there is no loss of confidentiality or integrity within any subsequent systems. |
| The www-data user can elevate its privileges because sudo is configured to allow the execution of the mount command as root without a password. Therefore, the privileges can be escalated to the root user. The risk has been accepted by the vendor and won't be fixed in the near future. |
| The scanner device boots into a kiosk mode by default and opens the Scan2Net interface in a browser window. This browser is run with the permissions of the root user. There are also several other applications running as root user. This can be confirmed by running "ps aux" as the root user and observing the output. |
| Elevation of privilege vulnerability in GE HealthCare EchoPAC products |
| IBM Common Cryptographic Architecture (CCA) 7.5.52 and 8.4.82 could allow an unauthenticated user to execute arbitrary commands with elevated privileges on the system. |
| The VAPIX Edge storage API that allowed a privilege escalation, enabling a VAPIX administrator-privileged user to gain Linux Root privileges. This flaw can only be exploited after authenticating with an administrator-privileged service account. |
| An improper privilege vulnerability was reported in a BIOS customization feature of Lenovo Vantage on SMB notebook devices which could allow a local attacker to elevate privileges on the system.
This vulnerability only affects Vantage installed on these devices:
* Lenovo V Series (Gen 5)
* ThinkBook 14 (Gen 6, 7)
* ThinkBook 16 (Gen 6, 7)
* ThinkPad E Series (Gen 1) |
| Screen 5.0.0 when it runs with setuid-root privileges does not drop privileges while operating on a user supplied path. This allows unprivileged users to create files in arbitrary locations with `root` ownership, the invoking user's (real) group ownership and file mode 0644. All data written to the Screen PTY will be logged into this file, allowing to escalate to root privileges |
| SAP GUI for Windows may allow the leak of NTML hashes when specific ABAP frontend services are called with UNC paths. For a successful attack, the attacker needs developer authorization in a specific Application Server ABAP to make changes in the code, and the victim needs to execute by using SAP GUI for Windows. This could trigger automatic NTLM authentication, potentially exposing hashed credentials to an attacker. As a result, it has a high impact on the confidentiality. |
| A vulnerability exists in multiple Radiometer products that allow an attacker with physical access to the analyzer possibility to extract credential information. The vulnerability is due to a weakness in the design and insufficient credential protection in operating system.
Other related CVE's are CVE-2025-14095 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required Configuration for Exposure:
Attacker requires physical access to the analyzer.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided a working proof-of-concept (PoC). Radiometer is not aware of any public exploit code at the time of this publication. |
| A vulnerability was found in H3C M2 NAS V100R006. Affected by this vulnerability is an unknown functionality of the component Webserver Configuration. The manipulation leads to execution with unnecessary privileges. An attack has to be approached locally. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor explains: "[T]he device only has configuration files and does not actually have boa functionality. It is impossible to access or upload files anonymously to the device through boa services". This vulnerability only affects products that are no longer supported by the maintainer. |
| setuid() does not affect libuv's internal io_uring operations if initialized before the call to setuid().
This allows the process to perform privileged operations despite presumably having dropped such privileges through a call to setuid().
This vulnerability affects all users using version greater or equal than Node.js 18.18.0, Node.js 20.4.0 and Node.js 21. |
| Sensitive data disclosure and manipulation due to unnecessary privileges assignment. The following products are affected: Acronis Backup plugin for cPanel & WHM (Linux) before build 619, Acronis Backup extension for Plesk (Linux) before build 555, Acronis Backup plugin for DirectAdmin (Linux) before build 147. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC models before version 241207101
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects all Iocharger AC EV charger models on a firmware version before 25010801.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified. |